The Series 16 is a commercial, cast-iron, gas-fired, hot-water boiler. The Series 16 is designed for use with a conventional chimney. The boiler is packaged with an electronic ignition system and has the option of either natural or LP gas. The Series 16 is available in firing rates from 325 to 585 MBH.

The Series 16 is shipped as a semi-packaged boiler with the boiler sections, base, and flue collector preassembled; final assembly is then easily completed in the field.

Available Summer 2013


Print Product Brief
Print Product Brochure

Air Conditioning Heating and Refrigeration Institute AHRI MemberConstructed and tested in accordance with ASME American Society of Mechanical Engineers Section FourIntertek ETL Listed United States
Type: Commercial
Heat Exchanger: Cast Iron
Fuel: Gas (Natural or LP)
Input: 325 - 585 MBH
Combustion Efficiency 80.0%
Venting: Atmostpheric
Ignition: Electronic
Trim: Water
Domestic Water: N/A
Burner: N/A
Configuration: Semi-packaged
Notes: Optional base available for installation on a combustible floor.
Optional CSD-1 control system available.

BOILER MODEL NO.  NO. OF SECTIONS  NATURAL OR LP GAS  WATER CONTENT
(GAL.) 
APPROX. SHIPPING
WEIGHT
(LBS)
Input
(MBH) 
HEATING CAPACITY
(MBH) 
AHRI NET RATING
(MBH) 
COMBUSTION EFFICIENCY
(%)
               
16-325  325
260
226
80.0  13.9  770 
16-390  390
312
271
80.0  15.9  875 
16-455  455
364
317
80.0  17.9  980 
16-520  520
416
362
80.0  19.9  1080 
16-585  10  585
468
407
80.0  21.9  1200 
               
 
  1. Ratings shown are for installations at sea level and elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
  2. Consult the manufacturer for installations having unusual piping and pickup requirements such as intermittent system of operation, extensive pipings systems, etc.
  3. AHRI Net ratings shown are based on normal piping and pickup allowance of 1.15.
  4. Maximum allowable working pressure is 50 PSI

MODEL NUMBER DIMENSIONS (INCHES)
             
16-325  23-3/4  11-7/8  8 27-13/16  18 60-5/16 
16-390  27-1/2  13-3/4  9 28-13/16  18 61-5/16 
16-455  31-1/4  15-5/8  9 30-13/16  20 63-5/16 
16-520 35
17-1/2  10 33-1/2  22 66
16-585  38-3/4 
19-3/8  10 33-1/2  22 66
             
   

1. Not for direct installation on combustible flooring. A heat shield is required and available for installation on combustible floors and on concrete floors which are over a material that is subject to melting (PVC, PEX Radiant Tubing, etc.). Not for installation on carpet even with a heat shield.
2. External draft hood supplied - may not be cut or altered.

Series 16 Left Side View

Series 16 Top View

 

Series 16 Front View


Series 16 Literature

Date: 1/7/2011 5:01:02 PM
Size: 666.13 kb


Series 16 Manual

Date: 11/29/2010 3:37:47 PM
Size: 5.57 mb


Series 16 Troubleshooting

Date: 1/15/2013 5:15:21 PM
Size: 87.03 kb