The Aruba-3 Series (AWI) residential, cast iron, hot water boiler is a fully-packaged, installer-ready product. The integral draft diverter provides a low profile design allowing the boiler to be installed in areas requiring a low clearance. This atmospheric, gas-fired boiler is for use with a conventional chimney. The Aruba-3 Series is packaged with the option of either natural or LP gas as well as an electronic ignition system.

Additionally, the Aruba-3 features a standardized Honeywell operating control with the unique option for placement on the right, left or top to accommodate any boiler room design.


Print Product Brief
Print Product Brochure

Air Conditioning Heating and Refrigeration Institute AHRI MemberConstructed and tested in accordance with ASME American Society of Mechanical Engineers Section FourIntertek ETL Listed Canada United StatesAir Conditioning Heating and Refigeration Institute AHRI Certified Logo
Type: Residential
Heat Exchanger: Cast Iron
Fuel: Gas Fired (Natural or LP)
Input: 37 - 295 MBH
Efficiency (AFUE) 80.0% - 82.6%
Venting: Chimney
Ignition: Electronic Ignition
Trim: Water
Domestic Water: N/A
Burner: N/A
Configuration: Packaged
Notes: Multiple piping options - right, left and top.
Designed for installation on combustible floors.

NATURAL OR LP GAS
   D.O.E HEATING CAPACITY(BTU/HR)IBR NET RATING (BTU/HR)AFUE %  
MODEL NUMBERNO. OF SECTIONSINPUT (BTU/HR)STANDING PILOTELECTRONIC IGNITIONWATER CONTENT (GALS.)APPROX. SHIPPING WEIGHT
(LBS)
AWI037237,00030,00026,00080.082.32.4217
AWI061361,00050,00043,00080.082.63.2267
AWI095495,00078,00066,00080.182.34.0317
AWI1285128,000105,00091,00080.282.04.7367
AWI1626162,000132,000115,00080.381.75.5417
AWI1957195,000159,000138,00080.481.46.3467
AWI2298229,000186,000162,00080.481.27.0517
AWI2629262,000212,000184,00080.580.97.8567
AWI29510295,000238,000207,00080.780.68.6617
         
 
  1. Altitudes above 2,000 ft. - ratings should be reduced at a rate of 4% for each 1,000 ft. above sea level (U.S.A. only). In Canada, boilers are certified for altitudes up to 2,000 ft. only.
  2. Specifications and dimensions are subject to change without notice.
  3. Consult factory if an unusual piping or pickup requirements exist.
  4. The Net I=B=R Water Ratings shown are based on a piping and pickup allowance of 1.15.

  DIMENSION  (INCHES)
MODEL NUMBER  A DEPTH FLOOR TO TOP OF JACKET FLUE COLLAR DIAMETER
         
AWI037 10 - 1/2 28 32 - 1/4 4
AWI061 11 - 3/4 28 32 - 1/4 4
AWI095 15 28 32 - 1/4 5
AWI128 18 - 1/4 28 32 - 1/4 6
AWI162 21 - 1/2 28 32 - 1/4 6
AWI195 24 - 3/4 28 32 - 1/4 7
AWI229 28 28 32 - 1/4 7
AWI262 31 - 1/4 28 32 - 1/4 8
AWI295 34 - 1/2 28 32 - 1/4 8

AWI Dimensions Standard Configuration
AWI Dimensions Top Configuration
AWI Dimensiions Left Side


Aruba 3 Literature

Date: 11/14/2013 2:37:08 PM
Size: 1.06 mb


Aruba 3 Installation Manual

Date: 11/14/2013 2:37:00 PM
Size: 824.5 kb


Gas Boiler User Manual

Date: 10/16/2012 9:24:01 AM
Size: 832.74 kb