Cabo 2 (CWD)


Products > Residential Boilers > Residential Gas > Cabo 2 (CWD)

Picture of the Cabo 2 (CWD)


The CABO-2 Series (CWD) residential, cast iron, direct-vent, hot water boiler is a fully-packaged, installer-ready product. The Bali Series is packaged with an electronic ignition system and has the option of either natural or LP gas. The Cabo-2 Series control supports priority zoning for an indirect water heater and an optional plug-in outdoor temperature reset control. Each model is ENERGY STAR® qualified.

A cast iron, wet-leg heat exchanger provides efficient heat transfer and reliability over the product's lifetime.




Print Product Brief
Print Product Brochure

EnergyStar ProductAir Conditioning Heating and Refrigeration Institute AHRI MemberConstructed and tested in accordance with ASME American Society of Mechanical Engineers Section FourIntertek ETL Listed United States
Type: Residential
Heat Exchanger: Cast Iron - Wet Leg
Fuel: Gas Fired (Natural or LP)
Input: 60 - 245 MBH
Efficiency (AFUE) 85.1% - 85.3%
Venting: Direct Vent
Ignition: Electronic
Trim: Water
Domestic Water: N/A
Burner: N/A
Configuration: Packaged
Notes: Energy Star qualified

NATURAL OR LP GAS
MODEL NUMBERNO. OF SECTIONSINPUT
(BTU/HR)
D.O.E HEATING CAPACITY
(BTU/HR)
IBR NET RATING
(BTU/HR)
AFUE %WATER CONTENT
(GALS.)
APPROX. SHIPPING
WEIGHT
(LBS)
        
CWD060360,00051,00044,00085.12.0280
CWD083482,50071,00062,00085.12.6315
CWD1105110,00094,00082,00085.23.1350
CWD1386137,500118,000103,00085.23.6385
CWD1657165,000142,000123,00085.24.2420
CWD1938192,500165,000143,00085.24.7475
CWD2209220,000189,000164,00085.25.2525
CWD24510245,000211,000183,00085.35.8580
        
 
  1. Altitudes above 2,000 ft. - ratings should be reduced at a rate of 4% for each 1,000 ft. above sea level (U.S.A. only).
  2. Specifications and dimensions are subject to change without notice.
  3. Consult factory if an unusual piping or pickup requirements exist.
  4. The Net I=B=R Water Ratings shown are based on a piping and pickup allowance of 1.15.

MODEL NUMBER "A" (INCHES) COLLAR DIAMETER (INCHES)
    INLET EXHAUST
       
CWD060 16 - 1/8 4 3
CWD083 19 - 3/4 4 3
CWD110 23 - 3/8 4 3
CWD138 27 4 3
CWD165 30 - 5/8 4 3 or 4
CWD193 34 - 1/8 4 3 or 4
CWD220 32 - 3/4 4 3 or 4
CWD245 41 - 3/8 4 4

CWD General Specifications


Cabo Literature

Date: 11/29/2010 2:12:04 PM
Size: 891.64 kb


Cabo Installation Manual

Date: 11/29/2010 2:13:06 PM
Size: 2.16 mb


Cabo Coaxial Terminal Manual Supplement

Date: 11/29/2010 2:12:14 PM
Size: 410.41 kb


Gas Boiler User Manual

Date: 1/18/2012 1:23:46 PM
Size: 853.5 kb