Freeport CT


Products > Residential Boilers > Residential Oil > Freeport CT

Picture of the Freeport CT


The Freeport CT Series boiler is a fully-packaged, installer-ready, 3-pass cast-iron, oil-fired, hot water boiler. The Freeport CT Series is designed for installation with a standard chimney. This boiler is available in heating capacities from 92-286 MBH. Some models of the Freeport CT boiler are ENERGY STAR® qualified. See the product ratings tab for more details.

The Freeport CT is available with a Beckett (standard) or Riello oil burner. Features include a 3-pass heat exchanger to maximize heat transfer and ease of service. The Freeport CT Series also includes a cast-iron burner swing door and Honeywell operating controls.




Print Product Brief
Print Product Brochure

EnergyStar ProductAir Conditioning Heating and Refrigeration Institute AHRI MemberConstructed and tested in accordance with ASME American Society of Mechanical Engineers Section Four
Type: Residential/Light Commercial
Heat Exchanger: Cast Iron
Fuel: Oil
Input: 0.75 - 2.50 GPH
Efficiency (AFUE) 84.0% - 87.6%
Venting: Chimney
Ignition: N/A
Trim: Water
Domestic Water: N/A
Burner: Beckett/Riello
Configuration: Packaged
Notes: 3 Pass Scotch Marine Design
Some models are ENERGY STAR qualified.

MODEL NUMBER NO. SECTIONS HEATING CAPACITY
(MBH)
IBR NET RATING
(MBH)
BURNER CAPACITY
GPH
AFUE % WATER CONTENT
(GALS.)
APPROX SHIPPING
WEIGHT
(LBS)
BECKETT RIELLO
                 
CT-3 3 92 80 0.75 86.6 86.6 4.2 443
CT-35* 3 120 104 1.00 84.7 84.7 4.2 443
CT-4 4 121 105 1.00 86.1 86.1 5.5 540
CT-45* 4 160 139 1.35 84.0 84.0 5.5 540
CT-5 5 162 141 1.35 86.1 86.1 6.8 643
CT-6 6 202 176 1.65 86.1 86.1 8.2 736
CT-7 7 243 211 2.00 86.1 - 9.5 833
CT-8* 8 286 249 2.50 85.3** - 10.8 919
                 
  CT-35 & CT-45 are up-fired versions of the CT-3 & CT-4
* Not Energy Star Qualified
**  AHRI Combustion Efficiency
  1. Specifications and dimensions are subject to change without notice.
  2. Consult factory if an unusual piping or pickup requirements exist.
  3. The AHRI Net Water Ratings shown are based on a piping and pickup allowance of 1.15.
  4. Firing rate in GPH based on having a heat value of 140,000 BTU/GAL.

MODEL NUMBER DIMENSION (INCHES) FLUE COLLAR DIAMETER
(INCHES)
A B*
       
CT-3 19 - 1/4 34 7
CT-35 19 - 1/4 34 7
CT-4 24 - 1/4 39 7
CT-45 24 - 1/4 39 7
CT-5 29 - 1/4 44 7
CT-6 34 - 1/4 49 7
CT-7 39 - 1/4 54 7
CT-8 44 -1/4 59 7
       
  * Dimension "B" is approximate due to varying burner lengths

CT SPEC DRAWING


Freeport CT Literature

Date: 2/23/2011 3:18:18 PM
Size: 1.04 mb


Freeport CT Installation Manual

Date: 11/29/2010 3:23:10 PM
Size: 2.03 mb


Freeport CT Troubleshooting

Date: 1/15/2013 5:15:10 PM
Size: 154.91 kb