CABO 2  SPECIFICATIONS

Dimensions


*air inlet collar located on center rear of CWD193 through CWD245

Specifications

Model
Number
NO. OF
SECS
AGA
INPUT
BTU/HR
D.O.E.
HEATING
CAPACITY
BTU/HR
IBR NET
WATER
RATING
BTU/HR
COLLAR
DIAMETER
WIDTH
A
(INCHES)
AFUE
(%)
SHIPPING
WEIGHT
INLET
(INCHES)
EXHAUST
(INCHES)
CWD060 3 60,000 51,000 45,000 4" 3" 16-1/8 85.1 280
CWD083 4 82,500 71,000 61,000 4" 3" 19-3/4 85.1 315
CWD110 5 110,000 94,000 82,000 4" 3" 23-3/8 85.2 350
CWD138 6 137,500 118,000 102,000 4" 3" 27 85.2 385
CWD165 7 165,000 142,000 123,000 4" 3" or 4" 30-5/8 85.2 420
CWD193 8 192,500 165,000 144,000 4" 3" or 4" 34-1/8 85.2 420
CWD220 9 220,000 189,000 164,000 4" 3" or 4" 32-34 85.2 525
CWD245 10 245,000 211,000 193,000 4" 3" OR 4" 41-3/8 85.3 580

Maximum Transfer Rates

Locating the Boiler

  • Clearances: Sides1", front 3", rear 1", top 12"
  • 6" clearance to air inlet collar when combustion air is supplied from indoors
  • Boiler may be installed directly on a non-carpeted combustible floor
  • Relief valve my not  be moved from factory location
  1. Altitudes above 2,000ft- rating s should be reduced at a rate of 4% for each 1000ft. above sea level (USA only), in Canada, boilers are certified for altitudes up to 2,000 feet only
  2. Please specify fuel (natural gas or LPG)
  3. Specifications and dimensions are subject to change without notice

Venting
Crown offers coaxial vent terminal kits for both horizontal and vertical venting.
Consult our installation manual for specific venting requirements.